Water level below the lowest visible part of the gauge
Zhongde LYF2.0/300-0.7, composite boiler (oil-fired at exhaust gas)
Posibleng sanhi
Feed failure or level control fault
Ano ang gagawin
Manual ng gumawa, p. 92Stop the burner immediately, close the steam valve slowly, cool down and inspect before restart
Tingnan ang assembly sa 3D model
Iba pang sira ng Zhongde LYF2.0/300-0.7
Brown water in the gauge glass / primingOil or dirt in the boiler waterSafety valve does not lift at set pressureSticking or wrongly set valveHeating surface red-hot or deformedOverheating, low water or scaleCoke or smoke in the furnaceBurner out of adjustmentWater level gauge leaksLoose nuts or worn cock packing
Mula sa manual ng gumawa na “EM-3 ZHONGDE BOILER”. Suriin ang orihinal sa barko bago magtrabaho.