JOWA F-2
淡化水矿化过滤器
The JOWA F-2 re-hardening filter removes solid particles from evaporator water and raises its pH to 7.0–8.5 to limit corrosion of pipes, heat exchangers and tanks. A stainless steel (AISI 316L) vessel is filled with filter sand and pH-adjusting material between top and bottom strainers; two three-way valves switch between service and back-flushing. The manual covers installation between evaporator and fresh water tanks, filling, start-up, back-flushing, shut-off, safety, spare parts for all sizes and the type approval.
点击模型上的零件,查看编号和用途。打开 3D 说明书
保养规程
Back-flushing the filter
- Turn both three-way valve handles upwards to reverse the flow. 第 5 页
- Flush for about 10 minutes or until fairly clear water comes out of the flushing outlet. 第 5 页
- Turn both handles back downwards for service. 第 5 页
First filling and start-up
- Fill sand through the upper manhole to about 10 cm above the bottom strainer, then pH material to about 15 cm below the top strainer. 第 3 页
- Fill with water through the inlet and back-flush until clear water comes out of the outlet. 第 5 页
- Set both handles downwards; the filter is in service. 第 5 页
保养周期
| 项目 | 周期 | 操作 | 说明书 |
|---|---|---|---|
| Back-flushing | once or twice a week depending on contamination | Flush about 10 minutes until clear | 第 5 页 |
| pH value | regularly | Check pH; top up pH material through the upper manhole as it is consumed | 第 5 页 |
技术参数
| pH after filter | 7.0–8.5 (approval: 6.5–8.5) | 第 3 页 |
|---|---|---|
| Vessel material | stainless steel SIS 2353 (AISI 316L) | 第 3 页 |
| Back pressure | at least 0.2 bar to prevent self-draining | 第 3 页 |
| Filling | sand about 10 cm over the bottom strainer, then pH material to about 15 cm below the top strainer | 第 3 页 |
| Sizes | F-75-2, 150-2, 300-2, 500-2, 750-2, 1500-2, 2000-2 | 第 26 页 |
来源:制造商说明书《EM-27 RE-HARDENING FILTER》,共 26 页。页码以原文为准。作业前请核对船上的说明书。