Bad smell from the unit
Hamworthy Super Trident ST6A, biološki uređaj za obradu otpadnih voda, imo mepc.2(vi)
Mogući uzrok
Anaerobic tank: compressor, air-lifts or diffusers not working, or too much sludge
Što učiniti
Priručnik proizvođača, str. 56Check compressor, sludge return air-lifts and diffusers; desludge
Ostali kvarovi Hamworthy Super Trident ST6A
Tank overflow / high level alarmDischarge pump failure, pipe blockage or excessive inflow (leaking WC flush valves)Poor effluent qualityLack of oxygen, killed bacteria by disinfectant cleaners, sludge not returning, too much flushing waterScum on the settling tankSkimmer or air-lifts not workingFoaming in the aeration tank and ventToo much cleaning agentDischarge pump gives no flowClosed valves, blocked suction, air leaks or loops in suction pipeReduced or irregular pump dischargeChoked impeller, valve or non-return valve partly closedAir gauge 0.2 bar above normal / relief valve blowingClogged diffuser elements or dirty filters
Prema priručniku proizvođača „Sewage treatment plant manual”. Prije rada provjerite izvornik na brodu.