Bad smell from the unit
Hamworthy Super Trident ST6A, bioloģiskā notekūdeņu attīrīšanas iekārta, imo mepc.2(vi)
Iespējamais cēlonis
Anaerobic tank: compressor, air-lifts or diffusers not working, or too much sludge
Ko darīt
Ražotāja rokasgrāmata, 56. lpp.Check compressor, sludge return air-lifts and diffusers; desludge
Citi Hamworthy Super Trident ST6A bojājumi
Tank overflow / high level alarmDischarge pump failure, pipe blockage or excessive inflow (leaking WC flush valves)Poor effluent qualityLack of oxygen, killed bacteria by disinfectant cleaners, sludge not returning, too much flushing waterScum on the settling tankSkimmer or air-lifts not workingFoaming in the aeration tank and ventToo much cleaning agentDischarge pump gives no flowClosed valves, blocked suction, air leaks or loops in suction pipeReduced or irregular pump dischargeChoked impeller, valve or non-return valve partly closedAir gauge 0.2 bar above normal / relief valve blowingClogged diffuser elements or dirty filters
Pēc ražotāja rokasgrāmatas “Sewage treatment plant manual”. Pirms darba pārbaudiet oriģinālu uz kuģa.
Lappuse tulkota automātiski. Detaļu numuri, kodi un lappuses ir kā oriģinālā.