SeaVint

Meiyo sensori

Temperatūras un spiediena sensori trauksmes sistēmai

Finished plan for the engine-room monitoring sensors: Pt100 thermo-resistance bulbs with measuring point list, 4–20 mA pressure transmitters with test pieces and gauge valves, Danfoss KPS thermostats and RT pressure switches. It includes specifications, maintenance and inspection intervals for the bulbs, zero and span adjustment of the transmitters, and setting of the thermostats (range and differential).

Noklikšķiniet uz detaļas modelī, lai redzētu tās numuru un nozīmi.Atvērt 3D rokasgrāmatu

Apkopes procedūras

Pressure transmitter zero and span

  1. Power the transmitter for 20 minutes. 35. lpp.
  2. Disconnect it from the pipe so it sees no pressure; output should be 4 mA ±1 % F.S.; if not, remove the blind screw and adjust ZERO. 35. lpp.
  3. Reconnect, apply maximum range pressure, output should be 20 mA; adjust SPAN if needed. 35. lpp.
  4. Repeat zero and span until both are correct. 35. lpp.

Setting a KPS thermostat

  1. Loosen the locking screw between the spindles. 38. lpp.
  2. Set the upper (function) temperature on the range spindle and the differential on the differential spindle, e.g. 95 °C with 5 °C differential for a cooling water alarm. 38. lpp.
  3. Retighten the locking screw; fit the sensor in its pocket with heat-conductive compound. 38. lpp.

Tehniskās apkopes intervāli

ObjektsKadDarbībaRokasgr.
Resistance bulbs — mechanical1 month after install, then 6 monthsInspect23. lpp.
Resistance bulbs — electrical and cleaning1 month after install, then yearlyCheck insulation and clean23. lpp.

Tehniskie parametri

Resistance bulbPt100, class B (DIN/IEC), tolerance ±(0.3 + 0.005 t) °C, 5 mA2. lpp.
Insulation≥ 10 MΩ at DC 500 V at normal temperature2. lpp.
Pressure transmittersDC 24 V supply, 4–20 mA output, ranges 0–4.0 / 1.6 / 1.0 / 0.6 MPa, −0.1–0.4 MPa3. lpp.
Transmitter accuracy check4 mA at no pressure, 20 mA at full scale, ±1 % F.S.35. lpp.
KPS thermostat contactsAC 10 A ohmic / 6 A inductive at 440 V, IP67, −40…+70 °C ambient38. lpp.

Avots: ražotāja rokasgrāmata “EM-38 THERMO RESISTANCE BULB-TRANSMITTER-THERMOSTAT-PRESSURE SWITCH”, 63 lpp. Lappušu numuri atbilst oriģinālam. Pirms darba pārbaudiet rokasgrāmatu uz kuģa.

Lappuse tulkota automātiski. Detaļu numuri, kodi un lappuses ir kā oriģinālā.