Pressure does not rise (stays unloaded)
Tanabe TASK, eļļas iesmidzināšanas skrūves kompresors korpusā
Iespējamais cēlonis
Pressure switch, solenoid or unloader seal ring fault
Ko darīt
Ražotāja rokasgrāmata, 36. lpp.Readjust, clean or replace
Citi Tanabe TASK bojājumi
Does not start or stops at onceControl panel fault, low voltage, thermal relay trippedAir receiver safety valve blowsUnloader pressure switch, unloader valve or solenoid faultSeparator safety valve blows (high oil pressure)Clogged separator cartridge, minimum pressure valve faultOverheat tripDirty cooler, low oil, fan stopped, blocked intake, thermo valve faultOil flows back to suction filter at stopUnloader solenoid fault or stop delay relay wrongHigh oil content in airClogged separator cartridge, blocked return line, overfillingHigh vibration or noiseWorn mounting rubbers, loose bolts, bearing damage
Pēc ražotāja rokasgrāmatas “EM-20-3 INSTRUCTION MANUAL FOR AIR COMPRESSOR”. Pirms darba pārbaudiet oriģinālu uz kuģa.
Lappuse tulkota automātiski. Detaļu numuri, kodi un lappuses ir kā oriģinālā.