ERR 2 — clock failure
JOWA SEAGUARD, alarmă de santină 15 ppm (monitor ows)
Cauză posibilă
Hardware failure
Ce trebuie făcut
Manualul producătorului, p. 22Switch off, remove the battery from the control unit for 24 h, switch on, set GMT time and date, refit the battery; otherwise replace the CPU board
Alte defecte JOWA SEAGUARD
ERR 4 — memory errorMemory card loose or faulty (corroded contacts)ERR 8 — sensor not connectedBroken/loose cable or faulty sensorERR 10 — sensor cleaning requiredNo clean water, dirty sensor, failed auto-flush, air bubbles, faulty sensorERR 20 — sensor temperatureTemperature outside +1…+60 °C or faulty sensorERR 40 — log truncatedLog recording interrupted by power failureERR 80 — unknown errorSoftware failure or no ID in the Information menuPPM: O/R — out of rangeValue outside 0–30 ppm, sample too dirty, faulty sensor
Din manualul producătorului „Manual JOWA SEAGUARD”. Înainte de lucru, verifică originalul de la bord.
Pagina a fost tradusă automat. Codurile de piese, codurile de eroare și paginile sunt ca în original.